Specifications:
Model |
Chamber Size |
Overall Size |
Net Weight |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg |
Kg/cycle |
Kg/cycle |
KVA |
|
MD-0.8Y |
680*1180*1000 |
2200*2000*1410 |
1480 |
35 |
280 |
3 |
MD-1.0Y |
680*1180*1250 |
2200*2000*1660 |
1630 |
40 |
300 |
4 |
MD-1.2Y |
680*1180*1500 |
2200*2000*1910 |
2030 |
45 |
320 |
4 |
MD-1.5Y |
680*1180*1870 |
2200*2000*2280 |
2230 |
50 |
350 |
4.5 |
MD-2.0Y |
1000*1200*1700 |
2800*2000*2110 |
2490 |
60 |
400 |
4.5 |
MD-3.0Y |
1000*1500*2000 |
2800*2200*2410 |
3050 |
90 |
500 |
5 |
MD-4.0Y |
1000*1500*2670 |
2800*2200*3080 |
3700 |
120 |
600 |
6 |
MD-5.0Y |
1000*1500*3340 |
2800*2200*3750 |
4600 |
150 |
700 |
8 |
MD-6.0Y |
1000*1500*4000 |
2800*2200*4410 |
5400 |
180 |
800 |
8 |
MD-8.0Y |
1000*1500*5340 |
2800*2200*5750 |
7000 |
240 |
1000 |
12 |
Description:
Vials and oral solution Steam Sterilizer is mainly used for the sterilization, leak test and washing
of ampoule, syrup and IV solution with small capacity. It adopts pressure steam as sterilizing
medium to achieve the uniform sterilization between 105127. This sterilizer adopts heating
mode of displacement and exhausting from multi-points to ensure the through elimination of cold
air in chamber, uniform and rapid heating and eliminate the dead corner caused by the existing
cold air. Leak test by vacuum and color water is adopted to improve the detection rate of waste
after sterilization, Meanwhile provides the documents system that meets 2010 version GMP
requirement.
Pre-vacuum phase to remove the cool air from the chamber to ensure the heating
uniform in the chamber
Intelligent automatically leak detecting and cleaning function during the sterilization cycle
to ensure the leaked bottles easily found and eliminated
Multiple special leak testing method suitable for different type bottles,
Vacuum test plus colour water test method suitable for clear bottles leakage test;
For the not clear bottles, just vacuum test is best selection
Clean and dry function is a useful optional for washing the bottles and dry them after color
water test.
Flexible loading system designed according to your special certain bottles to ensure
not only the heating even distribution in the chamber, but the maximum loading capacity
as well Flexible special design offered for you, considerable according to your total equipment
layout space and technical requirements, saving not only space, but energy and cost as well.
Applications:
Pharmacy factory terminal sterilization of injections, oral liquid medicines, oral liquid health care
products packed into ampoules, vials or tube shaped bottles etc.
Competitive Advantage:
Customized for size, design and installation. Offer full set documentation of IQ, OQ,PQ,OQ
ZHANGJIAGANG MEDPHARM MACHINERY LTD. [China (Mainland)]
Business Type:Manufacturer
City: Suzhou
Province/State: Jiangsu
Country/Region: China (Mainland)