SS304 Chamber Veterinary Autoclave With Bowie- Dick Test Vacuum Leak Test 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: MD-0.36

SS304  Chamber Veterinary Autoclave With Bowie-Dick Test Vacuum Leak Test 

SS304  Chamber Veterinary Autoclave With Bowie-Dick Test Vacuum Leak Test 

   

Description:

 

Steam Sterilizers are configured for prevacuum sterilization of heat- and moisture-stable materials used in medical centers. These units can be equipped with prevacuum,  Steam Flush Pressure Pulse (SFPP), gravity, liquid, and daily air removal test cycles which  use, for example, a Bowie-Dick test pack or a vacuum test to determine the effectiveness of removing air from 

a sterilizer chamber

 

Features:

 

  • 304 stainless steel construction - chamber and jacket
  • Fewer welds, resulting in less metal fatigue
  • Fully jacketed chamber to optimize even chamber heating and minimize condensation
  • Manual hinged door with easy-open locking mechanism
  • Steam-activated gasket to lessen the possibility of air entering the chamber
  • Easy access and loading
  • Easy-to-align loading system eliminates operator handling of hot loads

 

TESTING CYCLES

 

Warm-up Cycle:

 

This cycle is used to warm chamber to operating temperature 

prior to performing a Bowie-Dick Test cycle (or other operating cycles).

 

Bowie-Dick Test Cycle:

 

 This cycle is used for conducting Bowie-Dick tests. Recommended load is a properly prepared Bowie-Dick test pack. Preprogrammed cycle parameters cannot be adjusted by the user.

  • Sterilize temperature: 134°C
  • Sterilize time: 4 minutes 
  • Dry time: 3 minute

 

Vacuum Leak Test:

 

 This cycle is used for testing the vacuum integrity of the sterilizer piping. Sterilizer chamber  must be empty while running this test cycle. All timing is preprogrammed and cannot be adjusted

 

Specifications:

 

Model

MD-0.36

Door type

double door type

Door open method

Motorized Hinge Door

Chamber volume

360L

Chamber Size  

600*600*1000mm

Overall Size         

1500*1800*1340mm

Net Weight            

800kg

Steam               

25Kg/cycle

Water           

240Kg/cycle

Power(KVA)

2KVA

Sterilization temperature rage

105°C to 134°C

Sterilization time rage

 0---99 minutes

Vacuum times

 0---9 times

Drying time

 0---99 minutes

Components
 

SS304 built-in steam generator

Touch screen display

PLC control system

High effective liquid-ring vacuum pump

 

 

bigPhoto
 Mr. Ms. JULIET

Tel: 86-512-58688450
Contact to this supplier